お役立ち情報 技術情報 2026/11/19 technical column TC-08 – Basic Techniques of Vibration Analysis 1. Introduction In condition monitoring of rotating machinery, vibration amplitudes, such as shaft vibration and bearing vibration, are monitored continuously or periodically to identify changes in machinery condition and early signs of abnormalities. However, overall (OA) vibration amplitude alone does not provide sufficient information about the frequency components of vibration or shaft motion, making it difficult to identify the causes of abnormalities. Vibration waveforms are therefore acquired and analyzed using various techniques to estimate the causes of abnormal vibration and assess machinery condition. For large, high-speed rotating machinery, buffered outputs (vibration waveform signals) from vibration monitors are fed into vibration analysis and diagnostic systems to examine machine behavior during startup, shutdown, and steady-state operation (see Section 6 of TC-03). For general-purpose rotating machinery, fault diagnosis using frequency analysis and envelope analysis for detecting damage in rolling bearings are also important (see Sections 2-2 and 2-3 of TC-04). This article explains representative vibration analysis techniques and graphical presentations that form the basis of these analyses. 2. Representative Vibration Analysis Techniques Four representative vibration analysis techniques are described below. In detailed machinery vibration diagnosis, these methods are used in combination. For example, frequency analysis and phase analysis can be combined with changes over time or with rotational speed to produce various analytical plots. (1) Time domain analysis: Time waveforms, probability density functions of vibration amplitude, and other representations are used to analyze amplitude, temporal variations, impulsive characteristics, and waveform symmetry. (2) Frequency domain analysis: Fast Fourier transform (FFT) and other methods are used to identify the frequency components (spectral components) contained in a vibration signal. (3) Spatial domain analysis: Lissajous figures (orbit plots) and related representations are used to examine the spatial trajectory of the rotating shaft center during vibration. (4) Phase analysis: The vibration amplitude and phase angle of the rotational synchronous component (1X) are used to analyze vibration behavior as rotational speed and operating conditions change. Note : Whereas (1) through (3) refer to analysis in specific domains, (4) is not restricted to any one domain. Phase analysis generally uses the amplitude of the rotational synchronous component (1X) and its phase angle relative to a rotational phase reference signal. The vibration vector, defined by amplitude and phase angle, can be displayed in polar coordinates. However, this phase angle describes the phase relationship of vibration to the rotational phase reference signal; it does not directly indicate the direction of vibration in physical space. Phase analysis is closely related to time and frequency domain analysis. Combining amplitude and phase information from multiple measurement locations also enables evaluation of spatial vibration behavior. Accordingly, phase analysis is treated here as a separate analysis technique. 2-1. Time Domain and Frequency Domain Analysis A time waveform directly represents how vibration varies with time and is suitable for observing impacts, beating, and waveform distortion. A frequency spectrum, by contrast, is suitable for separating and observing individual vibration components. These complementary representations show the same vibration signal from different perspectives. Figure 8-1, reproduced from ISO 13373-2:2016 (1), provides an illustrative explanation of the relationship between the time and frequency domains. Viewed from direction A, the diagram represents the time domain: the hatched plane at the front shows the original vibration waveform, while the sinusoidal components making up that waveform are arranged behind it in ascending order of frequency. Adding all these sinusoidal components produces the original hatched waveform. Viewed from direction B, the diagram represents the frequency domain. Although order analysis is a form of frequency domain analysis, orders such as 1X, 2X, and 3X, which are based on rotational speed rather than absolute frequency, are also widely used for diagnosing abnormalities in rotating machinery (see Section 2-2 of TC-04). While Table 4-3 in TC-04 did not include abnormality causes specific to fluid-film journal bearings, Table 8-1 presents an example of a cause-and-effect matrix that also includes these causes (2). Figure 8-1:Relationship Between Time and Frequency DomainsTable 8-1: Example of a Cause-and-Effect Matrix (Including Abnormality Causes Specific to Fluid-Film Journal Bearings) 2-2. Spatial Domain Analysis and Orbits An orbit plot is one of the most common forms of spatial domain analysis. As shown in Figure 8-2, shaft vibration is measured simultaneously by two displacement transducers, X and Y, installed in mutually perpendicular directions. The resulting time waveform signals, shown in Figure 8-3(b), are combined and plotted in X-Y coordinates as shown in Figure 8-3(a). The resulting orbit represents the dynamic trajectory of the shaft center during rotation. Depending on vibration conditions, the orbit may be circular, elliptical, or more complex. Figure 8-3 illustrates the relationship among plots used for time, frequency, and spatial domain analysis. Figure 8-2:Schematic Illustration of Orbit Measurement Using an OscilloscopeFigure 8-3:Relationship Among Time Waveforms, Frequency Spectra, and Orbits2-3. Phase Analysis The phase angle of the rotational synchronous component (1X) is determined from the timing relationship between the vibration waveform and a phase reference signal obtained once per shaft revolution. The combination of the 1X vibration amplitude and phase angle constitutes a vibration vector. Changes in this vector provide important information about rotor dynamic characteristics and abnormal conditions. Figure 8-4 uses a simple model in which only the sinusoidal rotational synchronous component (1X) due to unbalance occurs during rotation, as illustrated in (a). It shows (b) the amplitude and phase angle derived from the phase reference and vibration waveform signals, and (c) the resulting vibration vector plotted on a polar plot. These concepts will be discussed in more detail in the next article. Figure 8-4:Relationship Among Rotor Phase Reference, Shaft Vibration Waveform, and Vibration Vector3. Representative Vibration Analysis Plots The following plots are commonly used for vibration analysis of rotating machinery. 3-1. Trend Plot Figure 8-5 shows an example of a trend plot. A trend plot displays monitored parameters, such as vibration amplitude, against time, with time on the horizontal axis and measured values on the vertical axis. It is used to identify long-term trends, periodic fluctuations, and changes before and after abnormal events. Figure 8-5:Example of a Trend Plot3-2. Orbit Plot For an explanation of orbit plots, see Section 2-2 and Figure 8-3(a). In vibration analysis systems such as infiSYS RV-200 and Kenjin, it is common to display the orbit alongside the time waveforms from which it was derived, as in the orbit and waveform plot shown in Figure 8-6. Figure 8-6:Example of an Orbit and Waveform Plot3-3. Polar Plot Figure 8-7 shows an example of a polar plot. It traces the vibration vector during machinery startup or shutdown. Because changes in amplitude and phase can be read from the plot, it is useful for assessing balance condition, vibration behavior during startup and shutdown, and critical speeds. However, rotational speed at each point is not directly available from the polar plot alone. Accordingly, these systems provide a function for annotating rotational speed at suitable intervals along the trace. Figure 8-7 compares vibration-vector trajectories during acceleration at startup before and after rotor balancing. Figure 8-7:Example of a Polar Plot3-4. Bode Plot Figure 8-8 shows an example of a Bode plot. It uses exactly the same data as the polar plot, but displays amplitude and phase in separate graphs against rotational speed on the horizontal axis. A Bode plot typically shows the vibration amplitude and phase angle of the rotational synchronous component (1X) as functions of rotational speed. It enables simultaneous observation of amplitude increases and phase changes when passing through a critical speed, making it useful for evaluating rotor vibration characteristics. Figure 8-8:Example of a Bode Plot3-5. Spectrum Plot Figure 8-9 shows an example of a spectrum plot. Vibration data acquired at a particular time or rotational speed are analyzed in the frequency domain. Frequency or rotational order is plotted on the horizontal axis (Figure 8-9 uses order), and amplitude on the vertical axis. A spectrum plot identifies the frequencies and orders at which vibration occurs and, for example, indicates how much of the 1X or 2X component is contained in the time waveform. It is therefore useful for estimating the causes of abnormalities in rotating machinery. Figure 8-9:Example of a Spectrum Plot3-6. Waterfall and Cascade Plots Figure 8-10 shows examples of waterfall and cascade plots. A waterfall plot, shown in Figure 8-10(a), displays spectra acquired at multiple times in a three-dimensional, time-sequenced representation. A cascade plot, shown in Figure 8-10(b), displays spectra in three dimensions against rotational speed. These plots allow changes in frequency components over time or with rotational speed to be observed. Waterfall plots use elapsed time as the additional axis, whereas cascade plots use rotational speed; both are useful for analyzing vibration during transient operation. Figure 8-10:Examples of Waterfall and Cascade Plots3-7. S-V Plot Figure 8-11 shows an example of an S-V plot. It displays vibration amplitude as a function of rotational speed, superimposing multiple traces for the OA value and components such as 0.5X, 1X, and 2X. This enables analysis of vibration conditions and is useful for assessing vibration behavior and critical speeds during machinery startup and shutdown. Figure 8-11:Example of an S-V Plot3-8. Campbell Diagram Figure 8-12 shows an example of a Campbell diagram. Rotational speed is plotted on the horizontal axis and vibration frequency on the vertical axis, with straight lines radiating from the origin to represent orders (1X, 2X, and so on). Vibration amplitude is represented by the size of circles. The diagram provides an overview of how vibration amplitude and frequency change with rotational speed and allows rapid visual identification of whether a vibration component follows a particular order or remains at a particular frequency. Figure 8-12:Example of a Campbell Diagram4. Conclusion In vibration analysis, it is important to evaluate vibration signals from the perspectives of time, frequency, space, and phase, and to select analytical plots appropriate to the operating and abnormal conditions. Building on the basic techniques introduced here, subsequent articles will explain vibration vectors, phase references, sampling, balancing, and related topics. References (1) ISO 13373-2:2016, “Condition monitoring and diagnostics of machines – Vibration condition monitoring – Part 2: Processing, analysis and presentation of vibration data”, International Organization for Standardization, 2016. (2) Matsushita, O., Tanaka, M., Kobayashi, M., Koike, H., Kanki, H., “The Second Volume of Vibration of Rotating Machinery: Applications of Analysis, Troubleshooting and Diagnosis”, Corona Publishing, 2012. (in Japanese) Column related products KenjininfiSYS 3.0infiSYS RV-200